iQ Control Box
10.18.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204143 REV 5 5
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
Power Assist at Closed Mode: Reduces the inial force required to iniate door moon when Magic Touch or
Power Assist is enabled.
00 = OFF
01 = ON at Closed Door Posion: When DPS contact is closed, Power Assist at Closed is enabled.
02 = Sensor Controlled: DMA1, DMA2, DMS1, DMS2, OHP and Power Close Cancel / Power Assist inputs will enable Power
Assist at Closed when sensor is acve.
Power Assist Enable: This feature allows the operator to assist the user so that the door is easier to open during
manual operaon.
Power Assist Open Braking: Sets the amount of resistance the operator provides as the door approaches full open when
Power Assist is enabled. Decreasing this parameter will provide greater resistance provided by the Power Assist funcon.
Power Assist Torque: Sets the amount of helping force during manual operaon.
Power Close Angle: The angle at which the motor starts to assist the spring while closing. If set to 90, the motor will always
be assisng from full open.
Power Close at Closed Enable: Power Close at Closed Enable is used to maintain the door pressing at full closed (state 22).
Power Close at Closed Torque: Power Close Torque is the torque used during Power Close at Closed operaon. This torque
must be set to comply with ANSI/BHMA door force requirements. This parameter sets the maximum current available to the
motor which is directly proporonal to the door force.
Power Close Check Angle: The angle at which the door starts to slow down to Power Close Check Speed. This parameter
typically is adjusted based on door weight and Power Close Speed seng. This value should be lower than the
Power Close Angle.
Power Close Check Speed: This is the speed used during normal operaon in the Power Close check state prior to
arriving at full closed. This parameter sets the target speed seng. Other parameters like Power Close Speed,
Power Close Check Angle, and Power Close Check Torque, as well as door properes like fricon, door length,
and door weight aect door speed.
Power Close Check Torque: The torque used during normal operaon in Power Close check state. This torque must be set
to comply with ANSI/BHMA door force requirements. This parameter sets the maximum current available to the motor
which is directly proporonal to the door force. This torque seng is used in conjuncon with Power Close Check Speed.
Power Close Enable: Power Close allows the motor to assist the spring close to help overcome wind and stack pressure.
This feature requires a Power Close Speed Module (part #517864) connected to the controller. Ensure forces are in
compliance with applicable ANSI/BHMA Standard. To achieve this, door mounted sensors may be required to disable Power
Close when a person is nearby.
Power Close Obstruction Time: The amount of me in increments of 0.1 seconds that the door applies force when almost
stopped or stopped (when the controller indicates a state of 18). Before increasing this parameter, check for mechanical
issues, as well as Power Close Speed, Power Close Torque, Power Close Check Speed, and Power Close Obstrucon Speed
parameter sengs.
Power Close Speed: The speed used during normal operaon in Power Close (state 18). This speed is set to change how
long it takes the door to reach the Power Close Check Angle. This parameter sets the target speed seng. Parameters such
as Power Close Torque and door properes like fricon, door length, and door weight aect door speed.
Power Close Torque: The torque used during Power Close operaon. This torque must be set to comply with ANSI/BHMA
door force requirements. This parameter sets the maximum current available to the motor which is directly proporonal to
the door force. This torque seng is used in conjuncon with Power Close Speed.
Safety Logic: Selects sensor type to be used for monitored or non-monitored applicaons. Monitored Sensors may require
use of alternate wiring.
Stall Sensor Ignore Position: Ignores the stall sensor input from a percentage of the total door open. The full open
posion is 100 percent.
Stall Torque: Stall Torque is the torque used aer obstrucon and during stall events in the state of “15” or “16”. This
parameter aects the amount of force the door takes to push open while in stall.
Unlock Time: The me that the lock/strike is unlocked. This me starts when the door begins to open. The total me that
the lock/strike is unlocked is the Lock Delay plus the Unlock Time. Unlock Time is 0 to 9.8 seconds. Each increment is 0.1
seconds. When set to 99 the lock/strike will stay unlocked unl the door returns to the closed posion (99 is the only value
that is based on door posion and not me).
Features and Functions (continued) = NOT SELECTABLE BY KEY PAD/PUSH BUTTONS