iQ Control Box
10.18.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204143 REV 5 15
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
Table 4. Magic Force/Magic Swing Configuration Codes
Index
Min.
Value
Max.
Value
Description Motor
Defaults
Low
Energy
Full
Energy
0 1 125 Open Speed** M1 32 61
1 1 125 Open Check Speed** M1 6 6
3 0 99 Open Check Length M1 20 30
4 0 99
Magic Touch Sensivity
(01= max. Sensivity)
M1 0 0
5 1 99
Magic Touch Hold Open Time
(25 sec. max. = 99%)
M1 16 16
6 1 99
Hold Open Delay
(25 sec. max. = 99%)
M1 22 6
7 0 99 Open Torque M1 35 60
8 0 99 Open Check Torque M1 35 60
9 0 99 Stall Torque M1 8 8
11 0 15 Safety Logic M1 0 0
12 0 1 2S Operaon M1 0 0
13 3 60
Open Obstrucon Time
(60 = 1.5 seconds)
M1 20 20
14 0 40 Open Acceleraon M1 20 10
15 0 10 Open Braking M1 8 8
16 0 50
Operate Delay
(0.1 sec. increments: 5.0 sec. max.)
M1 0 0
17 0 1 No Reverse on Obstrucon M1 0 0
18 0 50 Lock Delay M1 0 0
19 0 1 Manual Mode Sensor Override M1 0 0
20 1 125 Open Speed** M2 32 61
21 1 125 Open Check Speed** M2 6 6
23 0 99 Open Check Length M2 20 30
24 0 99
Magic Touch Sensivity
(01= max. Sensivity)
M2 0 0
25 1 99
Magic Touch Hold Open Time
(25 sec. max. = 99%)
M2 16 16
**Max value listed in table not accessible from keypad.
Table 4 Continued Next Page