10.18.2019
Table 2. iQ Mode Values
Code iQ Operational Mode
01 Dura-Glide door style—Single Motor
02 Dura-Glide door style—Dual Motor
03 Magic-Swing Door Style—Single Motor
04 Magic-Swing Door Style—Dual Motor
05 Magic-Force Door Style—Single Motor
06 Magic-Force Door Style—Dual Motor
07 Magic-Force Door Style—Single Motor Low Energy
08 Magic-Force Door Style—Dual Motor Low Energy
09 Fold door style--Single Motor
10 Fold door Style--Dual Motor
Description Index
iQ Mode Specic Door Operaonal Values - These depend upon the mode selected 00-89
Reserved 90-95
Command: Restart FIS. Entering 01 will cause FIS to restart. 96
Firmware: Entering 01 will display FE followed by two pairs of digits followed by FE.
For example, if the rmware is 0609, the controller will display FE 06 09 FE.
97
Command: Restart auto conguraon. Entering 01 sets the Control Box to A1, which keeps all
previous values and then the Control Box re-learns the encoder count.
98
Command: Lock. Entering 01 will lock all VALUE imports except this INDEX. This prevents
inadvertent changes to input values. VALUES may be unlocked by entering 00 in this INDEX.
99
Table 3. Index List