7. TROUBLESHOOTING GUIDE
SYMPTOM CAUSE REMEDY
Tool does not operate when switch
is pressed
Battery is defective Replace Battery
Battery is not fully charged Charge Battery
Battery is not fully seated Remove battery and re-insert.
Reset tool to home
Battery pack has reached
operating temperature limit
through continuous use or defect
Remove battery and allow to cool.
Mount battery and reset tool to
home
Tool does not return to initial
position when switch is released
Electrical malfunction Remove battery, wait ve seconds
and reinsert. Reset tool to home
Stuck Spindle Clutch Clean Spindle Clutch and Spindle
to operate smoothly
Tool stops before Neobolt is fully
swaged
Battery pack has reached
operating temperature limit
through continuous use or defect
Remove battery and allow to cool.
Mount battery and reset tool to
home
Setting load of fastener is beyond
tool capacity
Reset tool to home, adjust stroke
of tool to proper depth
Build up of debris inside the Nose
Equipment
Service and clean Nose Assembly
Selected tool stroke too short Adjust tool stroke
If tool is in electronic stroke
control mode: Mechanical stroke
adjustment pin may not be fully
retracted
Fully retract pin
Pintail is damaged Selected stroke too long Shorten stroke
Collet is worn out Replace collet
Tool does not return fully Build up of debris inside the nose
equipment
Service and clean Nose Assembly
Collet does not release pin Build up of debris inside nose
equipment
Service and clean Nose Assembly
Collet not installed correctly Remove nose housing and adjust
collet
Anvil is loose Tighten Anvil
Tool does not release collar from
anvil
Dirty or worn anvil Inspect anvil, clean or replace.