17
G
B
G. Safety valve:7KHVDIHW\YDOYHLVVHWWRDYRLGRYHUSUHVVXUL]DWLRQ
RIWKHDLUWDQNV7KLVYDOYHLVIDFWRU\SUHVHWDQGZLOOQRWIXQFWLRQ
XQOHVVWDQNSUHVVXUHUHDFKHVWKLVSUHVVXUHDo not attempt to
adjust or eliminate this safety device.
Any adjustments to this valve could cause serious injury. If
this device requires service or maintenance, see an Authorized
6HUYLFH&HQWHU
H. Handle for lifting/moving
I. WheelRQO\IRUPRGHOV³+<9´DQG³+<9´
J. Rubber foot.
3. SCOPE OF USE
The compressor is designed for generating compressed air for tools
RSHUDWHGE\FRPSUHVVHGDLU
Please note that our equipment has not been designed for use
LQ FRPPHUFLDO WUDGH RU LQGXVWULDO DSSOLFDWLRQV 2XU ZDUUDQW\ ZLOO
be voided if the machine is used in commercial, trade or industrial
EXVLQHVVHVRUIRUHTXLYDOHQWSXUSRVHV
7KHPDFKLQHLVWREHXVHGRQO\IRULWVSUHVFULEHGSXUSRVH$Q\RWKHU
XVH LV GHHPHG WR EH D FDVH RI PLVXVH 7KH XVHURSHUDWRU DQG QRW
the manufacturer will be liable for any damage or injuries of any kind
FDXVHGDVDUHVXOWRIWKLV
4. ELECTRICAL GROUNDING INSTRUCTIONS
7KLV SURGXFW VKRXOG EH HOHFWULFDOO\ JURXQGHG ,Q WKH HYHQW RI DQ
electrical short circuit, grounding reduces the risk of electrical shock by
SURYLGLQJDQHVFDSHZLUHIRUHOHFWULFDOFXUUHQW7KLVSURGXFWLVHTXLSSHG
with a cord having a grounding wire with an appropriate grounding
SOXJ7KHSOXJPXVWEHSOXJJHGLQWRDQRXWOHWWKDWLVSURSHUO\LQVWDOOHG
DQGJURXQGHGLQDFFRUGDQFHZLWKDOOORFDOFRGHVDQGRUGLQDQFHV
4.1 Connection of the mains plug
Important!
The wires in the mains lead fitted to this product are coloured in
DFFRUGDQFHZLWKWKHFRGHVKRZQLQILJ
Ɣ 7KHSLQSOXJPXVWFRPSO\WR%6$
Ɣ )XVHPXVWFRPSO\WR%6
If for any reason the 13 amp plug fitted to this product requires
replacement it must be wired in accordance with the following instruction:
Do not connect the brown (live) or blue (neutral) to the earth pin marked
‘E’
on the 3 pin plug.
&RQQHFWWKH%OXH ZLUHWRWKH WHUPLQDOPDUNHG1HXWUDO1&RQQHFW
WKH%URZQZLUHWRWKHWHUPLQDOPDUNHG/LYH/&RQQHFWWKH<HOORZ
*UHHQZLUHWRWKHWHUPLQDOPDUNHG(DUWK((QVXUHWKDWWKHRXWHU
insulation is gripped by the cord grip and that the wires are not trapped
ZKHQUHSODFLQJWKHSOXJFRYHU7KHPDLQVOHDGRQWKLVSURGXFWLVILWWHG
ZLWKD DPS%6$ SOXJ$DPS %6IXVHPXVW EH
ILWWHGLQWKHSOXJ
If in doubt consult a qualified electrician
7KHUHDUHQRXVHUVHUYLFHDEOHSDUWVLQVLGHWKLVSURGXFWH[FHSWWKRVH
UHIHUUHGWRLQWKHPDQXDO$OZD\VUHIHUVHUYLFLQJWRTXDOLILHGVHUYLFH
SHUVRQQHO1HYHUUHPRYHDQ\SDUWRIWKHFDVLQJXQOHVVTXDOLILHGWRGR
VRWKLVXQLWFRQWDLQVGDQJHURXVYROWDJHV
Warning!
For your protection if this product is to be used outdoors it should not
EHH[SRVHGWRUDLQRUXVHGLQGDPSORFDWLRQV'RQRWSODFHWKHSURGXFW
RQGDPSVXUIDFHVXVHDZRUNEHQFKLIDYDLODEOH)RUDGGHGSURWHFWLRQ
XVHDVXLWDEOHUHVLGXDOFXUUHQWGHYLFH5&'DWWKHVRFNHWRXWOHW
Note: If the mains cable requires replacing it must be replaced with
DQLGHQWLFDORQHDQGILWWHGE\DTXDOLILHGSHUVRQ
5. PRE-START PROCEDURES
Ɣ
([DPLQH WKH PDFKLQH IRU VLJQV RI WUDQVSRUW GDPDJH 5HSRUW DQ\
GDPDJHLPPHGLDWHO\WRWKHFRPSDQ\ZKLFKGHOLYHUHGWKHFRPSUHVVRU
Ɣ 9HULI\ WKDW WKH WDQNV KDYH EHHQ GUDLQHG DQG DUH FOHDU RI DQ\
PRLVWXUHRUGLUW
Ɣ 7KHFRPSUHVVRUVKRXOGEHVHWXSQHDUWKHZRUNLQJFRQVXPHU
Ɣ $YRLGORQJDLUOLQHVDQGORQJVXSSO\OLQHVH[WHQVLRQV
Ɣ 0DNHVXUHWKHLQWDNHDLULVGU\DQGGXVWIUHH
Ɣ 'RQRWVHWXSWKHFRPSUHVVRULQGDPSRUZHWURRPV
Ɣ 7KHFRPSUHVVRUPD\RQO\EH XVHGLQVXLWDEOH URRPVZLWKJRRG
YHQWLODWLRQDQGDQDPELHQWWHPSHUDWXUHIURP&WR&7KHUH
PXVWEHQRGXVWDFLGVYDSRXUVH[SORVLYHJDVHVRULQIODPPDEOH
JDVHVLQWKHURRP
Ɣ 7KH FRPSUHVVRU LV GHVLJQHG WR EH XVHG LQ GU\ URRPV ,W LV
prohibited to use the compressor in areas where work is conducted
ZLWKVSUD\HGZDWHU
)LWWLQJWKHZKHHONLW
,ISURYLGHGWKHZKHHONLWPXVWEHLQVWDOOHGDVVKRZQLQILJXUH
)LWWLQJWKHVXSSRUWLQJIHHW
,ISURYLGHGWKHUXEEHUIHHWPXVWEHILWWHGDVVKRZQLQILJXUH
5.3 Assembling the quick coupler
Tighten the quick coupler for regulated pressure to the coupling on the
RXWOHWDVVKRZQLQILJXUHVDEDQGF
6. OPERATING INSTRUCTIONS
6.1 Start-Up Procedures
9HULI\WKDWWKH2Q2IIVZLWFKLVLQWKHOSRVLWLRQ
9HULI\WKDWWKHWDQNDLUSUHVVXUHLVDW%$5DQG36,
$WWDFKWKHDLUKRVHWRWKHGLVFKDUJHOLQH
3OXJWKHXQLWLQWRDSURSHUO\JURXQGHGRXWOHW
5RWDWH WKH 2Q2II VZLWFK LQ I SRVLWLRQ ILJ 7KH FRPSUHVVRU
will automatically cycle on and off to keep the tank pressure
PDLQWDLQHG
$GMXVW WKH SUHVVXUH UHJXODWRU WR WKH SURSHU SUHVVXUH VHWWLQJ
UHTXLUHGIRUWKHDLUWRRO
6.2 Shut-Off Procedures
5RWDWHWKH2Q2IIVZLWFKLQWKHOSRVLWLRQILJ
8QSOXJ WKH SRZHU FRUG DQG YHQW DOO WKH DLU LQ WKH WDQN XVLQJ D
pneumatic tool, connected to the compressor through the quick
FRXSOLQJ
7. CLEANING AND MAINTENANCE
Warning!
Pull the power plug before doing any cleaning and maintenance
work on the appliance.
Warning!
Wait until the compressor has completely cooled down! Risk of
burns due to hot surfaces!
Warning!
Always depressurize the tank before carrying out any cleaning
and maintenance work.
7.1 Cleaning
Ɣ.HHSWKHVDIHW\GHYLFHVIUHHRIGLUWDQGGXVWDVIDUDVSRVVLEOH:LSH
the equipment with a clean cloth or blow it with compressed air at
ORZSUHVVXUH
Ɣ:HUHFRPPHQGWKDW\RXFOHDQWKHDSSOLDQFHLPPHGLDWHO\DIWHU\RX
XVHLW
Ɣ&OHDQWKHDSSOLDQFHUHJXODUO\ZLWKDGDPSFORWKDQGVRPHVRIWVRDS
'RQRWXVHFOHDQLQJDJHQWVRUVROYHQWVWKHVHPD\EHDJJUHVVLYHWR
WKHSODVWLFSDUWVLQWKHDSSOLDQFH(QVXUHWKDWQRZDWHUFDQJHWLQWR
WKHLQWHULRURIWKHDSSOLDQFH
Ɣ<RX PXVW GLVFRQQHFW WKH KRVH DQG DQ\ VSUD\LQJ WRROV IURP WKH
FRPSUHVVRU EHIRUH FOHDQLQJ 'R QRW FOHDQ WKH FRPSUHVVRU ZLWK
ZDWHUVROYHQWVRUWKHOLNH
7.2 Draining tank
The condensation water must be drained off each day by opening the
GUDLQYDOYHUHI(RQWKHERWWRPRIWKHSUHVVXUHYHVVHOILJ
9HULI\WKDWWKHFRPSUHVVRULVWXUQHG2II
+ROGLQJWKHKDQGOHWLOWWKHFRPSUHVVRUWRZDUGWKHGUDLQYDOYHVR
WKDWLW¶VVHWLQDORZHUSRVLWLRQ