Assignable Input and Output Functions
QB Expert Alpha Controller
142
Outputs
Description
*RUNDOWN
HOUR
This is the hour value of the last fastening cycle time. It asserts when the fastening cycle is complete (before the
IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN JOB
This value indicates the job in which the last fastening cycle was performed. It asserts when the fastening cycle
is complete (before the IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run
again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN
MINUTE
This is the minute value of the last fastening cycle time. It asserts when the fastening cycle is complete (before
the IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN
MONTH
This is the month value of the last fastening cycle date. It asserts when the fastening cycle is complete (before
the IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN
PART ID
This is the PART ID value of the last fastening cycle date. It asserts when the fastening cycle is complete (before
the IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN
SECOND
This is the second value of the last fastening cycle time. It asserts when the fastening cycle is complete (before
the IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.