SETUP Area
QB Expert Alpha Controller
54
Name This parameter sets the Service Set Identifier (SSID) for the access point in the QPM Expert
Alpha controller.
The maximum number of case sensitive, alphanumeric (ASCII) characters is 32. It is
recommended to use a value that best defines the station under test from other stations.
Use the up and down arrows on the keypad to insert characters. Use the right arrow to move
the cursor for the next character.
If left blank the default SSID for the QPM Expert Alpha controller is QB-serialnumber, where
serialnumber is the serial number of the controller; i.e. QB-032014007.
Password This parameter sets the encryption key needed to connect a wireless device to the access
point in the QPM Expert Alpha controller. Must be a minimum of 8 characters and no longer
than 63 printable characters or 64 hexadecimal digits.
Use the up and down arrows on the keypad to insert characters. Use the right arrow to move
the cursor for the next character.
This parameter can be left blank.
Region Select from the drop-down list the region of the world where the tool is operating. This
selects the correct frequency channels allowed by that region.
3.1.3.2.1 SHOW Button
Normally the password displays as dots when typed. To see the password press the SHOW interactive menu
button.
3.1.3.2.2 PAIR Button
Press the PAIR interactive menu button to initiate the pairing mode to a QPM Cordless Tool. This will switch the
access point to a pairing SSID while the Expert Alpha controller is in pairing mode.
To pair a QPM Cordless Tool after pressing the PAIR button ensure the QPM Cordless Tool is off by removing the
battery pack and re-installing the battery pack. Wake the QPM Cordless Tool into pairing mode by pressing and
holding the MFB and then tap the start trigger switch. Wait for the tone before releasing the MFB. The QPM
Cordless Tool will find the Expert Alpha controller and request to be added as a trailing spindle by turning on, then
off, the status lights in sequence. Accept the QPM Cordless Tool as a trailing spindle on the Expert. See Section
8.1 Connection” on page 164 to see how to accept the spindle as a trailing device.
Press the BACK interactive menu button when the pairing operation is complete to return the access point to
normal mode and the user defined SSID.
Use the right arrow to move to the next tab or press EXIT to save the changes and return to the Run screen. See
section “3.1.2.6 Exit” on page 52.
3.1.3.3 Serial Tab
Selects the function for the db-9 COM PORT connector on the bottom of the Alpha controller.