Shanghai STEP Electric Co., Ltd.
28
F06 Adjustment of door open limit range0-400
0
F06 < 200door-openning position<learnt door width
F06= 200door-openning position= learnt door width
200 < F06
400door-openning position>learnt door width
F07 Percentage of door open limit range0-100.0
When door opening to door width F07, Relay of door open limit will work, and
the door continues opening to real point of opening to position.
F08 Percentage of door door close limit range
0-100.0
When door closinging to door width F08, Relay of door door close limit will
work, and the door continues closing to real point of door close limit.
F09 Spare
F10 Frequency changing point range0-10.00
changing point of low speed and high speed Frequency in Closed loop control
F11 Low speed when door starts to open range0-300
The rotary speed of motor when door starts to open at a low speed
F12 Low speed when door starts to close range0-300
The rotary speed of motor when door starts to close at a low speed
F13 High speed when door starts to open range0-1500
The rotary speed of motor when opening door at a high speed
F14 High speed of closing door Setting range:
0-1500
The rotary speed of motor when closing door at a high speed.
F15 Low speed of stopping to open the door(the speed of opening door at a low
speed after energized) range0-300
The rotary speed of motor to open the door at a low speed when the
door-opening deceleration signal is effective in the door-opening course.
F16 Low speed of stopping to close the door(the speed of forcing closing door at a
low speed range0-300
The rotary speed of motor to close the door at a low speed when the door-closing
deceleration signal is effective in the door-closing course.
F17 Acceleration of opening door range1-30
Acceleration of rising segment in the door-opening curve when door is opening.
F18 Deceleration of opening door range1-30
Deceleration of declining segment in the door-opening curve when door is opening.
F19 Acceleration of closing door range1-30
Acceleration of rising segment in the door- closing curve when door is closing.