6. Assembly, Setup and Installation of the System
Environmental Conditions
The machine is solely suitable for the operation in dry, interior spaces.
Keep the environmental temperature of the machine dust-free. High dust exposure can cause dam-
ages to the system.
The humidity should be within normal limits for humidity indoors (40 to 60 %). Protect the machine
against wetness and humidity.
The ideal environmental temperature for the system lies between 18°C to 25°C, respectively from
64°F to 77°F.
Particularly protect the electronics against overheating by avoiding direct sun radiation or indirect heat-
ing up nearby a radiator.
Positioning the Machine
Place the machine on a suitable table or on a machine stand. To provide a comfortable working
height, we recommend a working height of approx. 840 mm. For a torsion-free stand, the surface of
the machine stand needs to be solid and even. The machine is to be secured in a way that it cannot
shift or fall down.
All movable parts of the machine must be able to operate collision-free.
The routing of the tool´s cables, such as with the milling motor, has to be effected in a way that the ca-
ble cannot be clamped between the guide ways of the machine. For this purpose, use the special Flexi
Guides™ on the top of the X-axis.
The machine has to easily accessible and operable. Especially the emergency switch has to be easily
accessible at all times.
Take care to ensure a sufficient illumination of the machine`s location and the workplace surrounding
the machine.
The PC controlling the machine has to be placed in the vicinity of the machine to have both in clear
view.