1.9 FE 7 remote control
The FE 7 enables
- the modification of the set room tempera-
ture for heating circuit 1 or 2 by ± 5 °C
- the operating mode to be changed.
The remote control comprises the following
control elements
z a rotary selector for changing the set
room temperature
z a rotary selector for the following settings
automatic mode
constant setback mode
constant day mode
The remote control is only effec-
tive, when the WPMi is in automatic
mode.
1.10 FEK remote control
The FEK is always required for oper-
ating the WPF with WPAC 1 in con-
junction with area cooling, e.g. underfloor
heating systems, etc. Apart from the room
temperature, it also determines the dew
point temperature to prevent the formation
of condensate.
26_03_01_0106
The FEK remote control enables
- the modification of the set room tempera-
ture for heating circuit 1 or 2 by ± 5 °C
- the operating mode to be changed
It comprises the following controls
z one rotary selector for changing the set
room temperature
z one key with the settings
automatic mode
constant setback mode
constant day mode
When the FEK is preset to one
specific heating circuit, then the pa-
rameters heating curve, room temperature
and heating program are hidden at the heat
pump manager WPMi.
26_03_01_0107
Heating and DHW programs
You may enter your own individual programs into the following tables.
Standard settings
At the factory, the heat pump manager is programmed with the following standard settings:
Switching times
1)
for heating circuit 1 and heating circuit 2 H1 / H2 (day mode)
Monday - Friday 6:00 h - 22:00 h
Saturday - Sunday 7:00 h - 23:00 h
ROOM TEMP 1/2
2)
Room temperature in day mode 20 °C
Room temperature in setback mode 20 °C
DHW program switching times
Monday - Sunday
3)
0:00 h - 24:00 h
DHW temperature
DHW DAY T 47 °C
DHW SETBACK T 10 °C
Heating curve slope
Heating curve 1 0.6
Heating curve 2 0.2
1) Only for switching times pair 1; switching time pairs 2 and 3 are preprogrammed.
2) Stiebel Eltron recommends systems without night setback; our systems are set up accordingly.
3)
Due to favourable heat pump tariff, when heating up during the night.
Heating circuit 1
Switching times pair I Switching times pair II Switching times pair III
Mo
Tu
We
Th
Fr
Sa
Su
Mo - Fr
Sa - Su
Mo - Su
Heating circuit 2
Switching times pair I Switching times pair II Switching times pair III
Mo
Tu
We
Th
Fr
Sa
Su
Mo - Fr
Sa - Su
Mo - Su
DHW program
Switching times pair I Switching times pair II Switching times pair III
Mo
Tu
We
Th
Fr
Sa
Su
Mo - Fr
Sa - Su
Mo - Su