9
INFO
OUTSIDE Outside temperature
ACTUAL ROOM T Actual room temperature for heating circuit 1 (HC1) or heating circuit 2 (HC2)
(will only be displayed if the FE7 remote control is connected)
SET ROOM T Set room temperature for heating circuit 1 or heating circuit 2
(will only be displayed if the FE7 remote control is connected)
REL HUMIDITY Relative humidity
DEW POINT TEMP Dew point temperature
ACTUAL DHW T Actual DHW temperature
SET DHW TEMP Set DHW temperature
ACTUAL RTRN T Actual heat pump return temperature - heating circuit 1
SET RTRN TEMP Set heat pump return temperature for heating circuit 1 (HC1). Fixed temperature is displayed for fixed temperature control
ACTUAL MIXER T Actual mixer flow temperature - heating circuit 2
SET MIXER TEMP Set mixer flow temperature - heating circuit 2
FIXED VALUE Fixed temperature - heat pump return
SET BUFFER T Set buffer temperature (Highest set value of heating circuits H1 and H2 (H3 if MSM is installed). Fixed temperature will be
displayed for fixed temperature control)
ACTUAL FLOW T Actual heat pump flow temperature
SET FLOW HEAT Set central heating flow temperature
ACTUAL SRCE T Actual source temperature
SET SRCE TEMP Minimum source temperature
DUAL MODE HEAT Dual-mode point - central heating
DUAL MODE DHW Dual-mode point - DHW
HEAT LIMIT Limit temperature - central heating
DHW LIMIT Limit temperature - DHW
SYST FROST PRO System frost protection temperature
HOT GAS TEMP Compressor outlet temperature
PRESSURE HD High pressure
PRESSURE ND Low pressure (only for triple phase)
HEAT AMOU TAG kWh
Compressor heat volume in heating mode over the last 24 hours in kWh (only for triple phase)
TTL HEAT AMOU MWh
Total compressor heat volume in heating mode in MWh (only for triple phase)
HEAT AMOU TAG kWh
Compressor heat volume in DHW mode over the last 24 hours in kWh (only for triple phase)
TTL HEAT AMOU MWh
Total compressor heat volume in DHW mode in MWh (only for triple phase)
TTL HEAT AMOU kWh
Total heat volume of electric booster heater in heating mode in kWh (only for triple phase)
TTL HEAT AMOU MWh
Total heat volume of the electric booster heater in DHW mode in MWh (only for triple phase)