44 | WPM 3 www.stiebel-eltron.com
INSTALLATION
Settings
12. Settings
12.1 Standard settings
The heat pump manager is pre-programmed at the factory with
the following standard settings:
Switching times for heating circuit1 and heating circuit2
(day mode) only the 1stswitching pair is pre-programmed.
Standard Setting range
Monday - Friday 6:00 - 22:00 0:00 - 23:59
Saturday - Sunday 7:00 - 23:00 0:00 - 23:59
Settings / Heating / HEATING CIRCUIT 1 / 2
Standard settings without night setback.
Comfort temperature 20 °C 5 - 30 °C
ECO temperature 20 °C 5 - 30 °C
Switching times for DHW program
Monday - Sunday 0:00 - 24:00 0:00 - 23:59
Settings / DHW / DHW temperatures
Comfort temperature 50 °C OFF / 50 - 70°C
ECO temperature 50 °C OFF / 50 - 70°C
Heating curve slope
Heating curve 1 0.6 0 - 5
Heating curve 2 0.2 0 - 5
12.2 Settings made
Use these tables to note down the individual values set by you.
12.2.1 Heating program, heating circuit 1
Switching time
pair I
Switching time
pair II
Switching time
pair III
Mon
Tue
Wed
Thu
Fri
Sat
Sun
Mon-Fri
Sat-Sun
Mon-Sun
12.2.2 Heating program, heating circuit 2
Switching time
pair I
Switching time
pair II
Switching time
pair III
Mon
Tue
Wed
Thu
Fri
Sat
Sun
Mon-Fri
Sat-Sun
Mon-Sun
12.2.3 DHW program
Switching time
pair I
Switching time
pair II
Switching time
pair III
Mon
Tue
Wed
Thu
Fri
Sat
Sun
Mon-Fri
Sat-Sun
Mon-Sun
12.3 Appliance handover
Explain the function of the appliance to users and familiarise them
with its operation.
Note
Hand over these operating and installation instructions
to the user for safe-keeping. Always carefully observe all
information in these instructions. They provide informa-
tion on safety, operation, installation and maintenance
of the appliance.