Servicing work every 1000 hours
Pump motor: clean and check the wear of the brushes
Test the insulation between the chassis and the electric motors
Test the insulation between the chassis and the electronic control
Fork lift height sensors: check and clean
On-board charger (if present): earthing and isolation circuit tests
Hydraulic system
Hydraulic system: replace the pressure filter
Pump unit: check mounting
Hydraulic system: check the oil level
Hydraulic system: check for any leaks
Hydraulic system: check the condition of the pipe lines
Load lift system
Mast: lubricate the sliding tracks of the mast and forks
Mast: check the mounting
Lift cylinders, chains, rollers and end stops: check the condition, mounting and operation
Lifting chain: clean, check, adjust and grease the chains
Forks: check that the forks are in good condition
Mobile chassis: check
Protective device: check the condition of the anti-shearing protective screen and check that it is
correctly mounted
Check the tightness of the mounting bolts of the straddles (EXP only)
Initial lift "i"
Initial lift: grease the rods and levers
Initial lift: check the linkage
Further maintenance operations every 3000 hours
Transmission
Reduction gear unit: check the mounting
Chassis, bodywork and fittings
Folding platform and side protection: check the dampers, the suspension and the safety stop
Hydraulic system
Hydraulic system: check the hydraulic oil
Hydraulic system: replace the controller filters
Electrical system
Ultrasonic height sensor for the DLC 3 system: replace the battery
Load lift system
Mast: service the lift mast and check the lateral clearance of the pins
Maintenance
5
Scheduled maintenance
12545758043484 EN - 11/2021 - 08