Stop the engine and, if needed, the heater
and combustionchamber.
Put on protective gloves.
Close the shutoff valve (1).
Remove the cap from the filler valve (4).
Open the shutoff valve (3)
Check the filling pistol thread for cleanli-
ness.
Connect the filling pistol to the filler valve
(4).
Open the main shutoff valve of the LPG sta-
tion and operate the pump motor or filling
pistol until the valve installed in the tank
stops the filling.
Capacity : approx. 35,0 litres
Release the filling pistol control immediately
and terminate the filling procedure.
Turn off the pump motor and the main shut-
off valve at the LPG station.
CAUTION
The LP-gas tank may only be filled until the metering
valve shuts off and not according to the reading on
the fuel level gauge (2).
Carefully remove the pistol from the filler
valve (4).
Screw the cap on the filler valve.
CAUTION
If problems or special incidents occur during the fill-
ing procedure, notify the responsible persons and
have the faults corrected.
Perform a leak test with leakage spray ac-
cording to the inspection and maintenance
instructions.