You can copy the original file to PC and if necessary modify the file names. As Fig. 4.7, for
example, shows, .INI file is the configuration file stored in the memory of S8. You can open also
the “CONFIG.INI” file as a simple text file and set some parameters of static mode: sampling
frequency, minimum elevation angle, etc. Please modify this parameters with care and do not
change any parameter which is not clear because you could compromise the correct working
of the receivers.
You can use the STONEX
®
Assistant
to download the raw data and set the parameters in a safer
way, as explained in Chapter V.
IV.6 Registration of the receiver
If the provisional license expired, you need to insert a new license code in the receiver for
continuing to use it. The license is composed of a 32 characters code. For inserting the new
license you can use RTK software STONEX
®
SurvCE: you have to enter into the submenu
“Equipment” “GPS utilities” “Send command”, then write the command
“SET,DEVICE.REGI,[license code]”.
However it is also possible to register the receiver using the STONEX
®
Assistant
, as explained
in Chapter V.