Objet500 User Guide 6 Operating and Maintaining the Objet500 3DPrinter
DOC-07027 Rev.E 6-62
TotestandcalibrateUVlampradiation:
1. StarttheUVCalibrationWizardfromtheOptionsmenu.
2. Inthefollowingscreen,selectCalibrateUVIntensitytoadjustthelamp’s
radiationleveltotheacceptablerange.
Figure6-88UVTest/Calibrationselection
3. Inthefollowingscreen,selecttheUVsensorandmeasuringdevicetobe
used.
Figure6-89UVdeviceselection
UV Measuring Device
WhenyouusetheStratasysUVsensorbox(TOL-03005-S),youconnect
ittotheprinter.ThewizardautomaticallymeasuresandcalibratestheUV
radiation.
Ifyouuseastand-aloneUVradiationmeter,youneedtomanuallyenter
thereadingsfromthemeterinthewizardscreens.