30 MA_441-1-2_A1_180830_en
4.14.3
When the thread trimmer is mounted, the needle position parameters and
parameter F-749 must be changed.
Adjustment of the needle position for the use of our thread
trimmer
Needle positions
Parameter
Value
P1E
036
P1A
061
P2E
273
P2A
298
After entering the code number "3112" for the supplier level:
- Select parameter F-451 and confirm with the "E" key
- Set the value according to table (Needle positions) and confirm with the
key "E"
- Go to the next parameter and set the value as described in the chart
(Needle positions) and continue this procedure up to Parameter F-454.
- Save the data by pressing the "P" key twice and exit the supplier level.
Starting point for the stepper motor F-749
Operation without thread cutter
Value 220 (Factory setting)
Operation with thread trimmer
Value 289
Starting point for the stepper motor F-749
- Select parameter F-749 and confirm with the "E" key
- Change the value to the value "289" and confirm with the "E" key
- Press the "P" key
Procedure to save the change
- Select parameter F-401
- change value to "1"
- Save the data by pressing the "P" key twice and exit the supplier level.
- Switch the control box off and on again so that the change is saved.