20 MA_VEB100-2-4-5_A5-3_230123_en.doc
3 Notes on repair and adjustments
C A U T I O N ! Danger of Injury!
Read the safety and operating instructions before performing
maintenance and/or repair work. Failure to comply with them
can lead to severe bodily injury.
3.1 Stitch plate assembly (Fig. 5)
A T T E N T I O N !
Switch off the machine electrically!
Stitch plates are adjusted at the factory and can be easily exchanged in their entirety.
When replacing needle guide(s), the adjusting dimensions must be rechecked using a
dial indicator. After removing the needle lever, the dial indicator is inserted into the
needle shaft and, by turning the handwheel, touches the surface of the needle guide.
We recommend purchasing the stitch plate dial indicator 00392.0517 as an accessory.
Fig. 5