43 MA_VEB100-2-4-5_A5-3_230123_en.doc
4.2 DAC Classic control for Strobel machines
Legend:
E = level / t= technician level; K= category of parameters; P= subcategory
E
K
P
Min
Max
Default
Unit
Description
Sewing foot lifting (FL)
t
03
11
0
255
255
Ms
Switch-on delay of the sewing
foot lift during machine
standstill
t
03
12
0,0
9,999
0,190
s
Switch-on delay of the sewing
foot lift at the end of the
seam
Softstart
t
05
00
120
1000
200
rpm
Softstart speed
t
05
01
1
99
2
Stiche
Number of softstart stitches
Motor
t
08
00
500
9999
1800
rpm
Maximum speed
t
08
05
0
1
1
-
Direction of motor rotation
0 = Left
1 = Right
t
08
10
-
-
Fig. 30
-
Reference position
t
08
12
0
359
286* - 296*
°
Needle in low position (bottom
dead centre) (position 1)
t
08
13
0
359
286* - 296*
Cutting
position
°
Thread lever top dead centre
(position 2)
For Strobel thread trimmer
E
K
P
Min
Max
Default
Unit
Description
Chain cutter
t
28
00
0
2
1
-
Mode of the chain cutterr
0 = Off
1 = On
2 = Clamps after cutting
t
28
01
0
255
0
Stitches
Delay at the beginning of the
seam (only if t 28 00 = 2)
t
28
02
50
999
180
Ms
Duty cycle of the chain cutter
(with t 28 00 = 1)
t
51
50
0
40
40
-
Setting the output function for
the output (machine connector
pin 18)
40 = Chain cutter

Table of Contents

Other manuals for Strobel VEB100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Strobel VEB100 Series and is the answer not in the manual?

Strobel VEB100 Series Specifications

General IconGeneral
BrandStrobel
ModelVEB100 Series
CategorySewing Machine
LanguageEnglish

Related product manuals