EasyManua.ls Logo

Structural Concepts Oasis B32 - Preventive Maintenance - Performed by Trained Service Providers - 5 of 5; Annual Maintenance for Clean Sweep Coil Cleaner

Structural Concepts Oasis B32
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31
ANNUAL PREVENTIVE MAINTENANCE INSTRUCTIONS
Optional Clean Sweep® Condensing Coil Cleaner:
Important! Disconnect power from case before cleaning the Clean Sweep® Condenser Coil Cleaner!
Remove front grille (by removing 4 screws).
Slide/roll out condensing unit assembly.
Remove the four (4) screws holding Clean Sweep® rails intact.
Remove the Clean Sweep® rail.
Wash rail and brushes in hot water and mild soap solution.
If brushes are worn, they must be replaced. Call Technical Service Department to replace.
Toll-Free number is listed at end of manual.
Caution! Coil fins are sharp. Handle with care!
Reattach Clean Sweep® rail to condensing unit (4 screws).
Slide/roll condensing unit assembly back under case.
Replace front grille to case in same manner it was removed.
See photos below.
(4) Screws
--- Above photos are taken after front grille has been removed from case ---
Brushes Rail
PREVENTIVE MAINTENANCE - TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY - 5 of 5

Table of Contents

Related product manuals