4
CAUTION! GFCI BREAKER USE REQUIREMENT
If N.E.C. (National Electric Code) or local code requires GFCI (Ground
Fault Circuit Interrupter), use a GFCI breaker in lieu of a GFCI receptacle.
CAUTION! LAMP REPLACEMENT GUIDELINES
LED and fluorescent lamps reflect specific size, shape and design.
Any replacements must meet factory specifications, resist breakage and
reflect similar appearance as lamps from factory.
CAUTION
PRECAUTIONS
This sheet contains important precautions to prevent
damage to unit or merchandise. Please read carefully!
See previous page for specifics on OVERVIEW,
TYPE, COMPLIANCE and WARNINGS.
WIRING DIAGRAM
Each case has its own wiring diagram folded and in its
own packet.
Location: Diagram may be near ballast box, field wiring
box, raceway cover, or other related location.
CAUTION! POWER CORD AND PLUG MAINTENANCE
Risk of electric shock. If cord or plug becomes damaged,
replace only with cord and plug of same type.
OVERVIEW / TYPE / COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING / PLUGS - PAGE 2 of 2
CAUTION! CHECK CONDENSATE PAN POSITION & PLUG
Water on flooring can cause extensive damage!
Before powering up unit, check and confirm the following:
Condensate pan is DIRECTLY UNDER condensate drain.
Condensate pan plug is securely plugged into receptacle.
Overflow pan has plug connected to its box. Units with
optional Clean Sweepmust have TWO PLUGS connected.
CAUTION! ADVERSE CONDITIONS / SPACING ISSUES
Performance issues caused by adverse conditions are NOT warranted.
To prevent damage to end panels due to condensation, apply industrial grade
silicone sealant and tightly join to opposite end panels. When not adjoining
cases, keep end panels at least 6” away from walls/structures. Rear panels
must also be kept at least 6” from walls and structures.
Case must not be exposed to direct sunlight or any heat source.
To maintain proper case temperature, keep case at least 15-feet from exterior
doors, overhead HVAC vents or any air curtain disruption.
CAUTION
CAUTION! DO NOT RELY ON THERMOMETERS OR
THERMOSTATS FOR PRODUCT (FOOD) TEMPERATURES.
Thermometers & thermostats reflect air temperatures ONLY.
For ACTUAL product (food) temperatures, use a calibrated food
probe thermometers ONLY.
For accurate readings, DO NOT use infrared food thermometers.