1000 Emergency Care Stretcher
1500 PACU Stretcher
MAINTENANCE MANUAL
For Parts or Technical Assistance
1–800–327–0770
IMPORTANT
File in your
maintenance
records

Table of Contents

Questions and Answers

  • M
    Mr. Gregory HopkinsJul 28, 2025
    How to fix Stryker Medical Equipment jack that will not raise to full height?
    • L
      laurie98Jul 28, 2025
      To address a Stryker Medical Equipment jack that won't raise to its full height, begin by adding hydraulic fluid as indicated on page 12. Additionally, inspect the equipment for any leaks that may be preventing it from reaching its maximum extension.
  • J
    Juan HermanAug 4, 2025
    What to do if Stryker 1000 Medical Equipment jack will not hold in raised position?
    • C
      Christina HaynesAug 4, 2025
      If your Stryker Medical Equipment jack fails to hold in the raised position, start by completely closing the needle valve. If the jack then holds, the solution is to replace valve #1, as detailed on page 14. However, if the jack still does not hold its position, proceed to replace valve #2, as instructed on page 15.
  • J
    Jonathan CarlsonAug 11, 2025
    Why Stryker 1000 jack will not pump up and the jack actuator rod does not move?
    • P
      patriciabarnettAug 12, 2025
      If the Stryker Medical Equipment jack won't pump up and the actuator rod remains stationary, begin by closing the needle valve. If the jack then pumps up, the remedy is to replace valve #1. Should the jack still fail to pump up after closing the needle valve, replace valve #3, as described on page 15.
  • J
    Jennifer BaileyAug 18, 2025
    What to do if Stryker 1000 jack will not pump up but the jack actuator rod does move when the pump pedal is activated?
    • J
      jodi17Aug 19, 2025
      If the Stryker Medical Equipment jack does not pump up, but the actuator rod moves when you activate the pump pedal, you should replace valve #2, as instructed on page 15.

Summary

Introduction

Warning, Caution, and Note Definitions

Explains the meaning of safety and operational terms used in the manual.

Preventative Maintenance

Service Information

Pneumatic Fowler Adjustment

Step-by-step guide for adjusting the pneumatic fowler mechanism.

Pedal Linkage Adjustment

Adjusting the pedal linkage for dual side and end control bases.

Caster Assembly Replacement

Instructions for replacing caster assemblies on the stretcher.

Hydraulic System Troubleshooting

Identifies common hydraulic system issues and their solutions.

Hydraulic Check Valve Replacement

Procedures for replacing hydraulic check valves #1, #2, and #3.

Assembly Drawings and Parts Lists

Warranty

Limited Warranty

Outlines the terms and conditions of the product's limited warranty.

Stryker 1000 Specifications

General IconGeneral
ManufacturerStryker
Model1000
ApplicationPatient Transport
TechnologyHydraulic Lift
CompatibilityStandard hospital beds
PortabilityMobile with locking casters