EasyManuals Logo

Studer RCC-02 User Manual

Studer RCC-02
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
Studer Innotec SA
RCC-02/-03
94 V4.4.0 User manual
Level
User
ref.
Parameter
Unit
12
24
48
Mod.
value
Factory
Min
Max
Factory
Min
Max
Factory
Min
Max
Expert
1484
System earthing (Earth - Neutral)
Expert
1485
Prohibited ground relay
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1486
Continuous neutral
No/Yes
No
-
-
No
-
-
No
-
-
Inst.
1628
Xtender watchdog enable
No/Yes
No
-
-
No
-
-
No
-
-
Inst.
1629
Watchdog delay
sec
60
10
300
60
10
300
60
10
300
Inst.
1550
Parameters saved in flash memory
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Inst.
1415
ON of the Xtenders
-
-
-
-
-
-
-
-
-
Inst.
1399
OFF of the Xtenders
-
-
-
-
-
-
-
-
-
Expert
1468
Reset of all the inverters
-
-
-
-
-
-
-
-
-
Expert
1282
MULTI XTENDER SYSTEM
Expert
1283
Integral mode
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1461
Multi inverters allowed
Yes/No
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1462
Multi inverters independents. Need reset {1468}
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1555
Battery cycle synchronized by the master
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1547
Allow slaves standby in multi-Xtender system
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1571
Splitphase: L2 with 180 degrees phaseshift
No/Yes
No
-
-
No
-
-
No
-
-
Inst.
1437
Minigrid compatible
No/Yes
No
-
-
No
-
-
No
-
-
Inst.
1577
Minigrid with shared battery energy
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Inst.
1556
is central inverter in distributed minigrid
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1522
GRID-FEEDING
Expert
1127
Grid feeding allowed
Yes/No
No
-
-
No
-
-
No
-
-
Expert
1523
Max grid feeding current
Aac
10
0
50
10
0
50
10
0
50
Expert
1524
Battery voltage target for forced grid feeding
Vdc
12
9.5
18
24
19
36
48
37.9
72
Expert
1525
Forced grid feeding start time
hh:mm
20:00
00:00
24:00:00
20:00
00:00
24:00:00
20:00
00:00
24:00:00
Expert
1526
Forced grid feeding stop time
hh:mm
20:00
00:00
24:00:00
20:00
00:00
24:00:00
20:00
00:00
24:00:00
Inst.
1610
Use of the defined phase shift curve for injection
No/Yes
No
-
-
No
-
-
No
-
-
Inst.
1622
Cos phi at P = 0%
Text
1
-
-
1
-
-
1
-
-
Inst.
1623
Cos phi at the power defined by param {1613}
Text
1
-
-
1
-
-
1
-
-
Inst.
1613
Power of the second cos phi point in % of Pnom
%
50
20
85
50
20
85
50
20
85
Inst.
1624
Cos phi at P = 100%
Text
1
-
-
1
-
-
1
-
-

Table of Contents

Other manuals for Studer RCC-02

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Studer RCC-02 and is the answer not in the manual?

Studer RCC-02 Specifications

General IconGeneral
BrandStuder
ModelRCC-02
CategoryRemote Control
LanguageEnglish