SUNFAR E300 SERIES 19
F3. 11
Low-volt protection
level
180 ~ 230V
360 ~ 460V
1
200
400
F3. 12
Over-volt limitation
action level
350 ~ 400V
700 ~ 800V
1
380
760
F3. 13
Current limit
amplitude level
150 ~ 250 (%) 1 200
F3. 14 Program version 1800 ~ 1899 1 1800
F4.0
Communication
setting (E300B
series)
The 1st part of LED: Baud rate
selection
0: Reserved 1: 1200 bps
2: 2400 bps
3: 4800 bps 4: 9600 bps
5: 19200 bps
The 2nd part of LED: Data
format selection
0: No check 1: Even check
2: Odd check
The 3rd part of LED: Protocol
selection
0: RS485 protocol
1: MODBUS communication
protocol
The 4th part of LED: Reserved
1 0114
F4.1
Master address
(E300B series)
0 30
1 1
F4.2
Master response
delay
0 1000 ms
1 5
F4.3
Communication
auxiliary function
setting
The 1st part of LED: Inverter
master and slave set
0: This inverter as slave
1: This inverter as master
The 2nd part of LED: Action
selection if communication
failure
0: Stop 1: Keep state
The 3rd and 4th part of LED:
Reserved
1 0010
F4.4
Communication
overtime checkout
time (E300B series)
0.0 50.00 Hz
0.01 3.00
F4.5
Linkage setting
proportion
0.1 10.0
0.1 1.0
Communication function parameter unit
F4.6 Reserved
E300 Series Mini-type Integrated Universal Inverter Manual

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sunfar E300-2S0022(B) and is the answer not in the manual?

Sunfar E300-2S0022(B) Specifications

General IconGeneral
BrandSunfar
ModelE300-2S0022(B)
CategoryInverter
LanguageEnglish

Related product manuals