SUNFAR E300 SERIES 53
1.4.6 Modify EEPROM parameter (order type 5
Data send: modify torque boost [F0.11]=6.0, store when stop.
Master
send
Header
Slave
addr.
Order
type
Operation
order
Data type Data type
Set
data
Check
sum
Tai l
Digit 1 2 1 2 1 2 4 4 1
2A 30 30 35 30 31 30 30 41
30 30
33 43
30 32
36 44
0D
E.g.
5A 00 00 05 00 01 00 00 0B
00 00
00
3C
00 00
00 4D
0D
Explain Header
Addr.
00
5 order
Slave FWD
running
F0
Parameter
unit
F0.11
Parameter
Data
set
Adding
hex
Tai l
Data return: slave receives data normally.
Slave
return
Header
Slave
addr.
Slave
correspond
State
feedback
Data type
Data
addr.
Set data
Check
sum
Tai l
Digit 1 2 1 2 1 2 4 4 1
2A 30 30 30 30 31 30 30 41
30 30
33 43
30 32
36 38
0D
E.g.
5A 00 00 00 00 01 00 00 0B
00 00
00 3C
00 00
00 48
0D
Explain Header
0 slave
return
Slave
receive data
Slave FWD
running
F0
Parameter
unit
F0.11
Data set
successfully
Adding
hex
Tai l