14) Reverse (mirror) Function
■ Indication Status of Operation Panel
■ Operation Order
※ Status that power is on.
※ Zigzag width displayed on the indication device.
※ Pattern was set to left scallop No.3 in advance.
※ Needle is at down stop location.
1. Press left scallop pattern key.
Pattern number and shape number are displayed on
the indication device and after a moment, zigzag width
is displayed.
2. Press PARA/SET key.
The indication device blinks.
3. Press left scallop pattern key.
Indication device blinks and pattern number and shape
number are indicated.
4. Select reverse function by pressing N2 key.
Indication device continuously blinks.
5. Set the changed value by pressing PARA/SET key.
6. Start sewing by pedaling to the front.
7. Stop while sewing (where reversion is made) and rotate
the sewing material to 90
°.
8. Set reverse location by pressing reverse button.
9. Start sewing by pedaling to the front again.
Power On Status
Stop Sewing and
Convert Direction (90°)
Sewing
Sewing
Indication Device
24