5) Parameter Changing Method and Classification
(1) General Sewing related Parameter Number (A Group)
※ Operate by pressing N1 key after turning on the power pressing PARA/SET key. Select desired number, press straight-line
pattern key and change parameter value. Then, store the changed value by pressing straight-line pattern key again.
No.
A-01
A-03
A-04
A-05
A-02
5000 spm
[1]Stitch : 200~900
[2]Stitch : 200~2700
[3]Stitch : 200~2700
[4]Stitch : 200~2700
[5]Stitch : 200~2700
0 : Impossible
1 : Possible
100~510spm
0 : Impossible
1 : Possible
0.1~10.0mm
0~255
100~510spm
0 : Impossible
1 : Possible
0~255。
4~1020ms
4~1020ms
4~1020ms
1~30S
4~1020ms
4~1020ms
4~1020ms
4~1020ms
4~1020ms
4~1020ms
4~1020ms
20~70%
20~70%
20~70%
20~70%
20~70%
4000 spm
200 spm
500 spm
1000 spm
1500 spm
2000 spm
100 spm
8.0mm
0
190 spm
24。
4ms
40ms
40ms
30s
4ms
200ms
500ms
64ms
500ms
100ms
500ms
50%
15%
50%
50%
50%
100smp
2spm
0.1mm
1
2spm
1。
4ms
4ms
4ms
1s
4ms
4ms
4ms
4ms
4ms
4ms
4ms
5%
5%
5%
5%
5%
Function and Description
Maximum sewing speed
Set speed of sewing start 1~5
(soft start setting)
Set whether to use automatic knee lifter
Speed of half-stitch
Set operation key lock function
Set maximum zigzag-width
Not use
Not use
Not use
Set XY feed start location
Set thread trimming speed
Set reverse rotation after thread trimming
Set reverse rotation angle after thread
trimming
Delay time after thread trimming
Wiper On time
Wiper Off time
Time taking to automatically rise presser foot
Presser foot rise time
Presser foot fall time
Tension release solenoid Full On time
Back tack solenoid Full On time
Wiper solenoid Full On time
Presser foot solenoid Full On time
Thread
trimming solenoid Full On time
Tension release solenoid duty
Back tack solenoid duty
Wiper solenoid duty
Presser foot solenoid duty
Thread
trimming solenoid duty
Setting Scope Shipping Status Unit
A-06
A-07
A-08
A-09
A-10
A-11
A-13
A-14
A-15
A-16
A-17
A-18
A-19
A-20
A-21
A-22
A-23
A-24
A-25
A-26
A-27
A-28
A-29
A-12
100smp
0: impossible
0: impossible
0: impossible
37