36
(8) Aux In Test Function
1. After selection test mode, make”t-08”to be displayed.
Set the mode by pressing half-stitch key.
2. Pressing knee-lifter key, indication lamp of end condense turns on or turn off, and pressing reverse switch(A button), lamp of
needle down stop turns on or turns off.
3. End test by pressing half-stitch key.
(9) X direction stepping motor motion Test(1)
---> jumping test
1. After selection test mode, make”t-09 to be displayed.
Set the mode by pressing half-stitch key.
2. Set repeat number and width by pressing N1 key as
shown in the figure.
Repeat number : 1~99 times (ex : 10 times )
Width : 0.1~8.0 mm (ex : 3.0 mm )
3. Pressing straight-line pattern key, it operates.
4. End test by pressing half-stitch key.
(10) X direction stepping motor motion Test(2)
--> moving test
1. After selection test mode, make”t-10 to be displayed.
Set the mode by pressing half-stitch key.
2. Set repeat number and width by pressing N1 key as
shown in the figure.
Repeat number : 1~99 times (ex : 10 times )
Width : 0.1~ 8.0 mm (ex : 3.0 mm )
Speed : 100~5000 spm (ex : 3000 spm )
3. Pressing straight-line pattern key, it operates.
4. End test by pressing half-stitch key.
Repeat number (1~99)
Width (0.1~8.0mm)
Repeat number (1~99)
Width(0.1~8.0mm)
Speed(100~5000spm)
Increase
Decrease
Run/Stop
Increase
Decrease
Run/Stop
forward
(CW)
Backward
(CCW)
(11) Speed Test Function
1. After selection test mode, make”t-11 to be displayed.
Set the mode by pressing half-stitch key.
2. Turning pulley by hands forward as shown in the
figure, straight-line indication lamp turn on , and
backward, straight-line indication lamp turn off.
3. End test by pressing half-stitch key.