159
4.5.3 If maintenance is needed
4.5.3.1 Clean air filter cartridge
In case of filter clogging, indicator on monitor
will flash to notify you to clean air filter.
Stop the machine at level ground, lower
bucket to ground.
Stop auto-idle switch to run the engine
unloaded at low speed for 5 minutes.
【Important】
Stopping engine improperly will cause
damages to turbocharger.
Set starting key to OFF position, stop the
engine and remove the key from starting lock.
Set pilot safety lock lever to LOCK position.
Loosen buckle (1) to remove air filter end
cover.
Remove outside filter (2), clap slightly with
hand. Never hit it with hard stuff.
Note
Minimize pressure of compressed air
(<0.2 MPa, 2kgf/cm
2
, let go of
personnel around to avoid scattered
metal particles, wear personal
protective articles including
goggles and protective glassed.
Use compressed air to clean outside filter (1),
following the wrinkle direction to blow air
outward.
Clean up the inside filter.
Install outside filter (1), end cover, fasten
clamp buckle (2).
Start engine; run it unloaded at low speed.
Check filter clogging indicator on monitor. If
this indicator illuminates, shut engine
immediately and replace outside filter (1).
Replace internal filter (3) the moment outside
filter (1) is replaced.

Table of Contents