54
(8) Items for regular check
No.
Items to check
Detail to check
Frequency
monthly
seasonally
1
all the fasteners
loose and drop or not
2
belt
tautness and abrasion
3
pipelines
gall or break
4
joints
gall or leak
5
condenser
jammed by dust or not
6
cluster
wear out, burn or not
7
Electromagnetic clutch (compressor)
skid or not
8
compressor
anomalous sound
9
quantity
of refrigerant
bubble in
the fluid-inspection lens
10
dust screen
dirty or jammed
Note:
(1) As figure 3.10.5 (left) shows, when check the tautness of the belt, press it by force in 15N. The
sinkage between 5mm to 7mm (4~5mm) is appropriate.
(2) As figure 3.10.5(right) shows, when check the quantity of the refrigerant, please judge it according to
the bubble in the fluid-inspection lens.
Refrigerant
Fluid inspection lens
Other conditions
note
Figure 3.10.5