EasyManua.ls Logo

SUNWARD SWE80B - Storage

SUNWARD SWE80B
196 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
55
filling
amount
photos/figures
Condition description
The
moment
of start
working
After
shut
down
Too much
Fluid inspection lens is
clear with no bubble at
the moment of start,
working or after shut
down.
Air outlet is not cold
enough, condenser
inlet is very hot and
the condenser outlet is
like the environment
temperature, the
pressure at both sides
is high (especially the
high pressure side)
Check
and
release
the
excessive
refrigerant
Slightly
much
Fluid inspection lens is
clear with no bubble,
bubble appears at start
and 10 minutes after
shut down.
no need to
check and
repair
Proper
amount
Fluid inspection lens is
clear with no bubble
when working, a few
bubbles appear at start
and in 10 seconds after
shut down.
Air outlet is cold,
condenser inlet is
very hot, condenser
outlet is hot or warm,
air intake duct is cold
with normal pressure
at both sides.
Slightly
insufficient
A few bubbles appear
during work
Extremely
insufficient
Too many bubbles
appear during work
Air outlet is not cold
enough, condenser
inlet is not hot
enough, condenser
outlet is like the
environment
temperature, air
intake duct is warm
and the pressure of
high pressure side is
very low.
Check,
repair and
fill
refrigerant

Table of Contents

Related product manuals