Chapter 9 Plug-in type electromagnetic flowmeter series
www.supmea.com
been widely used in industrial sections such as chemical industry, chemical
fiber, metallurgy, chemical fertilizer, paper making, water supply and drainage,
sewage treatment, etc. and in automatic control of the production process.
9.2. Product form and composition
The product type is magnetic insertion. It is connected with the pipeline through a
mounting base, a ball valve, a compression nut and a positioning screw. Sensor
measurement can be divided into two types of structure: measurement tube type
and plane electrode type. The measuring tube type sensor is suitable for
measuring the cleaning medium; the planar electrode type is suitable for
measuring the liquid flow rate containing other impurities in the medium.
9.3. Main technical specification
(1) Applicable pipe diameter:
200~2000mm
(2) Flow rate measurement range:
0~1 to 0~10m/s, the full scale is continuously adjustable in the range of
1~10m/s.
(3) Measurement accuracy:
When the full-scale flow rate is 1 m/s, the accuracy is ± 2.5%.
(4) Conductivity of the measured medium: > 50μS/cm
(5) Working pressure: 1.6Mpa
(6) Electrode material:
Molybdenum-containing stainless steel 0Cr118Ni12Mo2Ti, Hastelloy c-276,
titanium Ti, and the like.
(7) Measuring tube (measuring head) material: ABS
(8) The highest temperature of the measured medium: ABS60℃
(9) Shell protection level: It complies with the relevant provisions of IP68 of
GB-08-84 standard.
(10) Sensor output signal: 0.209mVp-p/1m/s.
(11) The maximum transmission distance between the sensor and the converter is