It means the re-leveling speed when the lift is in the door zone. Because the length of leveling
plate is different in different system, the parameter adjusting can assure the landing accuracy of
re-leveling. It is used when chooses the re-leveling function through FE-32..
F3-11
Low-speed running Default 0.250m/s Min. Unit 0.001m/s
Setting Range 0.100~0.630m/s
It can set the low speed of running when the lift is running in inspection or shaft auto-tuning.
F3-12
Switching position of the NO.1 up
force reducer
Default 0.00m Min. Unit 0.01m
Setting Range 0.00~300.00m
F3-13
Switching position of the NO.1
down force reducer
Default 0.00m Min. Unit 0.01m
Setting Range 0.00~300.00m
F3-14
Switching position of the NO.2 up
force reducer
Default 0.00m Min. Unit 0.01m
Setting Range 0.00~300.00m
F3-15
Switching position of the NO.2
down force reducer
Default 0.00m Min. Unit 0.01m
Setting
Range 0.00~300.00m
F3-16
Switching position of the NO.3 up
force reducer
Default 0.00m Min. Unit 0.01m
Setting Range 0.00~300.00m
F3-17
Switching position of the NO.3
down force reducer
Default 0.00m Min. Unit 0.01m
Setting Range 0.00~300.00m
NICE3000 can set 3 pairs of switches of force reducer at most. Its setting position is: the
sequence is followed by the installation of NO.1, NO.2, and NO.3 force reducer s
witches from
the end to the middle of the shaft. That means the switch of the NO.1 is built near the terminal
landing.
In the low-speed lift, there may be only one pair of switches of force reducer. And there are two
or three pairs of switches of force reducer in the high-speed lift. The system can self-motion
monitor the running speed when lift run to the switching position of force reducer, and p
revent
car and counterweight from resting the butter because of the abnormity speed.
This parameter of distance means the distance from switch position to the lowest oor. It can
self-motion note according to the lift auto-tuning.