EasyManuals Logo

Suzhou Monarch Control Technology MCTC-GCB-A User Manual

Default Icon
183 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
Function parameter description NICE3000 User Manual
134
the larger the gain will be in the same condition. The controller can identify the driving and
brake state according to the signals of weight conductor, and then work out desirable torque
compensation values.
When the system uses analog weighing, these group parameters are used for adjusting
starting. Details of adjusting ways are as follows:
When motor is in driving state, If the lift rolls back wh
en starts, increase F8-03; if the lift rushes
to start, reduce F8-03.
When motor is in brake state, if the lift rolls back when starts, increase F8-04; if the lift rushes
to start, reduce F8-04.
F8-05
Car load Default 0 Min. Unit 1
Setting Range 01023
F8-05 is the read only parameter, reflecting the load state in car. The parameter is the
NICE3000 sampling value of load. If F5-36 setting is less than 2, set F8-05=0.So F5-36 must
be set right when using preset torque compensation function.
F8-06
Car no load setting Default 0 Min. Unit 1
Setting Range 01023
F8-07
Car full load setting Default 100 Min. Unit 1
Setting Range 01023
This group function codes can set the AD sampling value of analog when the car is in no load
and full load condition.
: If F8-06=F8-07, full load and over load is invalidation.
F8-08
Anti-nuisance function Default 0 Min. Unit 1
Setting Range 01
0This function forbidden;
1Allowable. This function must work with weighing sensor or weighing switch. If the car
order number is over the person number in car plus 3, the system clear up all orders, and each
person according to 70 Kg.
F8-09
Power failure rescue speed Default 0.050m/s Min. Unit 0.001m/s
Setting Range 0.0000.100m/s
When the lift is in the emergency state, it will run to leveling position in the speed. Please note
that the speed shouldnt be too high in the rescue course, or it may affect the normal work of
UPS. The speed is determined by the power of UPS.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suzhou Monarch Control Technology MCTC-GCB-A and is the answer not in the manual?

Suzhou Monarch Control Technology MCTC-GCB-A Specifications

General IconGeneral
BrandSuzhou Monarch Control Technology
ModelMCTC-GCB-A
CategoryController
LanguageEnglish

Related product manuals