Those parameters mentioned above are the interior time of NICE3000.This clock can count
time when theres power failure.Nice3000 can complete many special functions with time by
this clock such as fastigium service, etc. So users should set this parameter right by actual time
when rst electrify.
Function code Name Setting Range Default Min. Unit
F9-09 Accumulative working
time
065535h 0 1
F9-11 RUN times high bit 09999 1 1
F9-12 RUN times low bit 09999 0 1
They are total accumulative actual lift working time and running times. These function
parameters are read only and user isnt allowed to amend them. Lift accumulative run times =
run times high bit ×10000 + run times low bit.
6.11 FA Group Keyboard Setting Parameters
FA-00
Small keyboard display selection Default 0 Min. Unit 1
Setting Range
0Reversal display, physics oor
1Positive display, physics oor
2Reversal display, external call data
3Positive display, external call data
There are 3 bit LED displays at NICE3000 main control panel. User can change its display
direction by changing this function code; thereby its convenient to control the design of the
cabinet.
No matter how to fix the main control panel, you can look through it easily. When
the setting is 0 or 1, small keyboard displaying data is the number of physics oor .When the
setting is 2 or 3,small keyboard displaying data is external call data.
FA-01
Run display 1 Default 65535 Min. Unit 1
Setting Range 065535
This function code is made up of a binary number with 16 emic that display 16 kinds of running
state parameters. Each parameter is controlled by one binary number,1 expresses that
display this parameter,0 expresses that dont display this parameter. If want to display
parameter as the following list, relevant binary number should be s
et as follows:
Binary bit Parameter
Display or
not
Binary bit
setting
Binary bit Parameter
Display or
not
Binary bit
setting
Bit0
Running
speed
Display 1 Bit8
Output
terminal
Not
display
0
Bit1
Rated
speed
Display 1 Bit9
Currently
oor
Not
display
0
Bit2
Bus
voltage
Display 1 Bit10
Currently
station
Not
display
0
Bit3
Output
voltage
Not
display
0 Bit11 Car load Display 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suzhou Monarch Control Technology MCTC-GCB-A and is the answer not in the manual?

Suzhou Monarch Control Technology MCTC-GCB-A Specifications

General IconGeneral
BrandSuzhou Monarch Control Technology
ModelMCTC-GCB-A
CategoryController
LanguageEnglish

Related product manuals