FC-04
Error self-resetting times Default 0 Min. Unit 1
Setting Range 0~10
This function code can set the system self-resetting times when there’s system error. If the
system error times are over this value, the system will stay and wait for service.
0:It means that there’s no self-resetting function in the system.
FC-05
Interval time for resetting Default 5s Min. Unit 1s
Setting Range 2~20s
The interval time between the beginning of the fault and the automatic fault resetting, and the
waiting time between two fault automatically reset.
Function code Name
Setting
Range
Default Min. Unit
FC-06 First error information 0~3199 0 1
FC-07 First error month and day 0~1231 0 1
FC-08 Second error information 0~3199 0 1
FC-09
Second error month and
day
0~1231 0 1
┆ ┆ ┆ ┆ ┆
FC-24 Tenth error information 0~3199 0 1
FC-25
Tenth error month and
day
0~1231 0 1
FC-26 Latest error information 0~3199 0 1
FC-27 Latest error speed
0.000~
3.000m/s
0.000 0.001m/s
FC-28 Latest error current 0.0~999.9A 0.0
0.1A
FC-29 Latest error bus voltage 0~999V 0 1V
FC-30
Latest error month and
day
0~1231 0 1
FC-31 Latest error time 0~2359 0 1
This group function codes can note the latest 11 times error code, oor and time. The error
information is made up of 4 bit, the higher 2 bit mean the car stopping oor when error occurs,
and the lower 2 bit mean error code. For example: If the latest error information noted by FC-26
is 1
035, it means that the latest error code is Err35 and the latest error oor is the tenth oor.
FC-28~FC-31 record the outputting current, bus voltage and the idiographic time when the
latest error happens. The error’s type and meaning refers to chapter 8.