Function Explanation2)
Standard Function
Serial
number
Function name Function introduction Remark
1
Maintenance
Operation
Elevator access to the overhaul state, the system
automatically canceled and the operation of automatic
doors. By the upper (lower) line will enable the
elevator button to overhaul the speed of movement of
the point (down) operation. Release the button to stop
the lift immediately
Standard
Settings
2 Direct
stopping
To the principle of distance, Automatically generate the
smooth curves from start to of parking, no crawling,
directly stop in the leveling position
Standard
Settings
3
The best curve
generated
automatically
Systems automatically computing the most suitable
for the principle of human-machine function curve
according to the distance needed to run, and is not
subjected to restrictions on short
oor and the number
of constraints
Standard
Settings
4
Self-rescue
leveling
When the elevator is in a state of non-maintenance,
and did not stop at the leveling. If it meets the safety
requirements to run .the lift will automatically run
slowly to the nearest oor area, and then open the
door
Standard
Settings
5
Attendant
operation
Through the toggle switch in operation panel can
choose the driver op
eration, the driver can choose
the direction and other functions (such as straight
running function) The elevator close the door under
the condition of the driver sustained press the close
button.
Standard
Settings
6
Fire return to the
base oor
Receive the fire signal, the elevator will not respond
to any calls and inside command .the elevator run the
fastest way to the fire station and then open t
he door
and stop
Standard
Settings
7
Firemen Operation
In the operation of fire mode, the door does not
automatically open or close. Only press the button can
make the door action. The lift only response to one
command in car once. Only when the elevator open
the door stopped at the base station , reset the fire
switch and fireman switch, the lift can run normally
Function
Selection
8 Testing running
Tes
t run including new lifts fatigue test run, ban the
door action ,ban respond to outside-call , shielding of
end station limit switch, shielding of overloading signal,
etc
Function
Selection
9
Independent
running
Elevator does not response to outside –call and close
the door automatically (when the elevator in parallel
control and group control, In order to supply special
services for specific persons
to carry VIP persons or
goods. Press the independent running button then the
elevator out of group control, independent running)
Function
Selection
10
Emergency rescue
running
For the elevator motor which Human force upgrading
the car with rated load lager than 400N Set emergency
electrical running switch and operation to replace
manually upgrading.
Function
Selection