Installation and wiring NICE3000 User Manual
74
Terminal Name Instruction
COP
CTB communication
indicator
when communication well between MCB and
CTB, COP indicator lighten (green)
HOP Hall call indicator
when communication well between MCB and
HCB, HOP indicator lighten (green)
MODBUS Parallel indicator The parallel communication is normal (green)
X1X24 Input signal indicator when external input, indicator lighten (green)
Y1Y6 Output signal indicator when si
gnal output, indicator lighten (green)
terminal listc)
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
C
N
1
X17
X18
X19
X20
X21
X22
X23
X24
M
AI
C
N
9
24V
COM
MOD
+
MOD-
CAN+
CAN-
C
N
3
15V
PGM
PGA
PGB
PGM
PE
C
N
6
Y1
M1
Y2
M2
Y3
M3
Y4
M4
Y5
M5
Y6
M6
C
N
7
Chart 4-5 MCTC-MCB-A Terminal Denition
Plug CN1and CN9 instructiond)
Terminal Name Instruction
X1~X24
digital signal input
function selection
1.photocoupler isolation input
2.input resistance : 4.7K
3.input voltage range1030V
4.input current limit :5mA
terminal function decided by F5-01~F5-24

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suzhou Monarch Control Technology MCTC-GCB-A and is the answer not in the manual?

Suzhou Monarch Control Technology MCTC-GCB-A Specifications

General IconGeneral
BrandSuzhou Monarch Control Technology
ModelMCTC-GCB-A
CategoryController
LanguageEnglish

Related product manuals