AMI CACE
Default Values
A-96.250.871 / 120417 73
10. Default Values
Operation:
Sensors: Filter Time Const.: ................................................................. 20 Sec
Hold after Cal.:......................................................................... 0 sec
Relay Contacts Alarm Relay .................................................. same as in Installation
Relay 1/2...................................................... same as in Installation
Input.............................................................. same as in Installation
Logger: Logger Interval:.............................................................. 30 Minutes
Clear Logger:................................................................................ no
Display: Screen 1 and 2; Row 1: ................................................. Cond 1(sc)
Screen 1 and 2; Row 2:.................................................. Cond 2(cc)
Screen 1 and 2; Row 3:........................................................... None
Installation:
Sensors Miscellaneous; Calculations: ........................................................ no
Miscellaneous; Meas. unit ..................................................... µS/cm
Sensor Parameters; Sensor 1 and 2;Cell Constant...... 0.0415 cm
-1
Sensor Parameters; Sensor 1 and 2; Temp. corr. ................ 0.00 °C
Sensor Parameters; Sensor 1 and 2; Cable length ................. 0.0 m
Sensor Parameters; Sensor 1; Temp. comp.; Comp: ........Ammonia
Sensor Parameters; Sensor 2; Temp. comp.; Comp: ...Strong Acids
Signal Output 1 Parameter:...................................................................... Cond 1(sc)
Current loop:..................................................................... 4 –20 mA
Function:.................................................................................. linear
Scaling: Range low:............................................................0.000 µS
Scaling: Range high: ......................................................1000.00 µS
Signal Output 2 Parameter:...................................................................... Cond 2(cc)
Current loop:..................................................................... 4 –20 mA
Function:.................................................................................. linear
Scaling: Range low:............................................................0.000 µS
Scaling: Range high: ......................................................1000.00 µS
Alarm Relay: Conductivity; Cond. 1 (sc) and Cond. 2 (cc):
Alarm high: .....................................................................3000.00 µS
Alarm low:...........................................................................0.000 µS
Hysteresis:............................................................................10.0 µS
Delay: ...................................................................................... 5 Sec
Sample Temp: (Temp. 1 and Temp. 2)
Alarm High:............................................................................ 160 °C
Alarm Low:................................................................................. 0 °C