EasyManuals Logo

SYMEO LPR-1DHP User Manual

Default Icon
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
SYMEO Local Positioning Radar System
LPR-1DHP
Product Documentation
Web Server for LPR-1DHP units with TCP/IP interface
Copyright © Symeo GmbH 2012
Page 26 of 40
manufacturer.
User
User ID for access to the TCP/IP port. It has been set to "symeo" by the
manufacturer and cannot be changed.
Password
Enter the new password here if you want to change the password. The
password has been set to "54all2u" by the manufacturer.
Repeat
Password
Enter the new password again here if you want to change the password.
Extended system access („Remote Access“) enables console access via Telnet, SSH
(Secure SHell), SCP (Secure CoPy) and via the serial port. This enables extended system
information to be retrieved and troubleshooting to be carried out. We recommend that you
disable all functions that are not required..
In extended system access, the user "SYMEO" has 'ROOT' privileges, i.e.,
full access to the system. Depending on the settings made, the system can
also be damaged and such damage may or may not be reparable. If you
have any questions, please contact the SYMEO technical department.
The enormous range of functions that are available to console access means that only some
can be documented here. To find out more, please contact your IT administrator or Symeo
Support.
7.2.5 „Miscellaneous“ Area
Timezone
If a NTP-server is available and the IP-address of the NTP-server is entered
you can choose the time zone of the LPR-1DHP station. It is also possible
to enter the time zone manually.
7.2.6 „Special Functions“ Area
Restore
default
Click this button to restore the settings made by the manufacturer.
Click the "Execute" button (Restore factory default settings) in the
"Special functions" area to cancel all changed settings and restore the
factory settings.
The settings made by the manufacturer are only activated after a reboot of
the LPR-1DHP station. This means that changes of the settings (i.e. IP-
address) are possible.
The settings affected will be deleted and set directly to the
factory settings.
When the factory settings have been restored, it may be
necessary to repeat the initial commissioning process of the system .
Reboot
system
To accept the settings the LPR-1DHP station must be rebooted. Click the
button Reboot System to reboot the system.
Before you reboot the system the settings must be loaded to

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYMEO LPR-1DHP and is the answer not in the manual?

SYMEO LPR-1DHP Specifications

General IconGeneral
BrandSYMEO
ModelLPR-1DHP
CategoryAccessories
LanguageEnglish

Related product manuals