097-58001-02 Revision C – August 2005 TimeProvider User’s Guide 171
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
INPDISQ The specified input was
Disqualified or Qualified
as a possible system
reference. The fault
condition must be
continuously present for
the Fault Delay Time
(FLTDELAY) before
disqualifying the input
as a possible reference.
After INPDISQ is set the
alarm clears when the
input signal is fault free
for the Clear Delay Time
(CLRDELAY).
T1 NSA FLT
DELAY
YES MN MN MN
INPLOS The 1PPS from GPS is
LOS. The LOS must be
continuously present for
the Fault Delay Time
(FLTDELAY) before
disqualifying the input
as a possible reference.
After INPLOS is set, the
alarm clears when the
input signal is LOS free
for the Clear Delay Time
(CLRDELAY).
T1 NSA IMMED NO MN MN MN
INPPHASE The specified input port
has a excessive phase
measurement that is
disqualifies it from being
used.
T1 NSA IMMEDNO MNMNMN
EXDSC
Input has had excessive
discontinuities. This is
indicated when there are
more than 3 signal faults
of the same type within a
5 minute window. The
alarm clears when the 5-
minute window contains
less than 3 alarms of the
same type.
T1 NSA IMMEDNO MNMNMN
FFOFF Input has exceeded the
Fractional Frequency
Offset threshold.
T1 NSA IMMEDNO MNMNMN
Table 6-7. Alarms (Continued)
Alarm ID
Or
CONDTYPE
Alarm Condition
Description
AID
TYPE
Service
Affecting
Error
Delay
Default
Error
Delay
Editable
Alarm Default
Level
SSU PRS SUB