097-58001-02 Revision C – August 2005 TimeProvider User’s Guide 105
Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
Autonomous Message
TP-SSU 03-10-24 10:54:44
A 1183 REPT EVT
“PRS,EQPT:NA,QLEVEL,NSA,003-10-24 10-54-44:\"USER
ASSIGNED QUALITY LEVEL HAS CHANGED,1\””
;
Setting the Input Priority Level
The PRIORITY level works together with the QLEVEL parameter (described in
Setting the Input Quality Level, on page 104) to determine the switching strategy.
The PRIORITY level is the second factor the TimeProvider uses to determine which
input to use when the original primary input becomes unavailable.
Use the ED-SYNC command to set the PRIORITY level of the selected reference.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-SYNC::PRS:TS1000::PRIORITY=2;
ED-SYNC::INP1:TS1000::PRIORITY=2;
ED-SYNC::INP2:TS1000::PRIORITY=2;
These commands set the PRIORITY for each input to the same value; if you also
provision the QLEVEL to the same value, then you set up a non-revertive switching
strategy.
Autonomous Message
TP-SSU 03-10-24 10:56:00
A 1184 REPT EVT
“PRS,EQPT:NA,PRIORITY,NSA,03-10-24 10-56-00:\"PRIORITY
HAS CHANGED,2\””
;
Manually Selecting the Reference
Use the ED-SYNC command to manually select the reference. To select the
reference, you must first set the REFMODE keyword to FORCED, as described in
Controlling Automatic Reference Switching, on page 102.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
<aid> <keyword> <value> Description Default value
PRS
INPp (p = 1 | 2)
GPS
Input ports
PRIORITY 2 | 3 | 4 Sets the priority for
the selected input
1

Table of Contents

Other manuals for Symmetricom TimeProvider 1100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1100 and is the answer not in the manual?

Symmetricom TimeProvider 1100 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1100
CategoryClock
LanguageEnglish

Related product manuals