097-58001-02 Revision C – August 2005 TimeProvider User’s Guide 101
Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
Autonomous Message
TP-SSU 03-10-24 10:45:15
A 1179 REPT EVT
“GPS,EQPT:NA,FRMTYPE,NSA,03-10-24 10-45-15:\"GPS MODE HAS
CHANGED,AUTO\””
;
To manually set the location of the receiver, you must enter the latitude, the
longitude, and the altitude (in m) in the same command, using commas to separate
the parameters.
Sample Command
ED-EQPT::GPS:TS1000::POS=30-28-34.0N,97-50-16.0W,333.0;
Autonomous Message
TP-SSU 03-10-24 10:45:15
A 1179 REPT EVT
“GPS,EQPT:NA,FRMTYPE,NSA,03-10-24 10-45-15:\"GPS LOCATION
HAS CHANGED,MANUAL\””
;
Setting the Input Frequency
Use the ED-SYNC command to provision the input PRS frequency.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-SYNC::PRS:TS1000::FRMTYPE=5M;
Autonomous Message
TP-SSU 03-10-24 10:46:01
A 1179 REPT EVT
“PRS,EQPT:NA,FRMTYPE,NSA,03-10-24 10-46-01:\"INPUT
FRAMING TYPE HAS CHANGED,5M\””
;
<aid> <keyword> <value> Description Default value
PRS PRS input provisioning
FRMTYPE 1.544 M | 2M
(2.048 MHz) | 5M
| 6.312 M | 10M
Provisions the input
frequency of the PRS
input
2M

Table of Contents

Other manuals for Symmetricom TimeProvider 1100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1100 and is the answer not in the manual?

Symmetricom TimeProvider 1100 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1100
CategoryClock
LanguageEnglish

Related product manuals