Mode Header Suffix*
and Data Description Data
Output Waveforms
U0 Sine
U1 Triangle
U2 Squarewave
U3 Fixed base-line positive squarewave
U4 Fixed base-line negative squarewave
U5 DC; Ramp (Model 8021)
Program Parameters
FRQ Program output frequency HZ, KHZ, MHZ
AMP Program output amplitude MV, V
OFS Program output offset MV, V
(Model 8021 only) WID Program pulse width NS, US, MS, S
(Mode 8022 only) CAR Program carrier Level %
STP Program sweep stop HZ, KHZ, MHZ
SWT Program sweep time NS, US, MS, S
RPT Program internal trig. generator per. NS, US, MS, S
MRK Program sweep marker HZ, KHZ, MHZ
(Model 8020 and 8022 only) DCO Program dc output level MV, V
Review Parameters
VFRQ Display output frequency
VAMP Display output amplitude
VOFS Display output offset
(Model 8021 only) VWID Display pulse width
(Mode 8022 only) VCAR Display carrier Level
VSTP Display logarithmic sweep stop
VSWT Display sweep time
VRPT Display internal trig. generator per.
VMRK Display logarithmic sweep marker
(Model 8020 and 8022 only) VDCO Display dc output level
Response Data Query
FRQ? Interrogate output frequency HZ, KHZ, MHZ
AMP? Interrogate output amplitude MV, V
OFS? Interrogate output offset MV, V
(Model 8021 only) WID? Interrogate pulse width NS, US, MS, S
(Mode 8022 only) CAR? Interrogate carrier Level %
STP? Interrogate sweep stop HZ, KHZ, MHZ
SWT? Interrogate sweep time NS, US, MS, S
RPT? Interrogate internal trig. generator per. NS, US, MS, S
MRK? Interrogate sweep marker HZ, KHZ, MHZ
(Model 8020 and 8022 only) DCO? Interrogate dc output level MV, V
STT? Interrogate machine status
Table 4-5. Device-Dependent Command Summary (continued)
* Suffix Data is optional.
IEEE-488.2 Operation Model 8020