EasyManua.ls Logo

Takeuchi TL230 - Page 149

Takeuchi TL230
208 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-29
MAINTENANCE
If the fluid level cannot be checked by fluid
level lines:
Remove the caps (2) and look into the
fluid filler holes to check the fluid level. If
the fluid is below the sleeve (3), be sure to
add distilled water up to the bottom edge
of the sleeve (3).
Proper level (A)
If the fluid reaches up to the bottom edge
of the sleeve (3), the surface tension
causes the fluid to swell and the plate
appears as if it is distorted.
Level too low (B)
If fluid does not reach up to the bottom
edge of the sleeve (3), the plate looks
laminar, not distorted.
4. Check the terminals for looseness and
dirt.
Replenishing
When adding distilled water
, do so before
starting operations in order to prevent
freezing.
1. Remove the bolts (a) and open the
radiator (b).
EVERY 50 HOURS
2. Engage the stay (c) onto the hook (d) to
secure the radiator (b).
3. Remove the indicator (1) and the caps (2),
and then add distilled water until the upper
level (H).
4.
Install the indicator (1) and check that it
indicates blue.
5.
Clean the exhaust hole on the caps (2),
and then tighten them securely.

Table of Contents