OPERATING PROCEDURES
6-7
Models 8752 and 8756 with HorizonĀ® Pump
Operating Procedures
6
9. Attach one end of the air line to the air compressor
fitting and the other end to the air inlet fitting of the
check valve assembly.
Figure 6-25
10. Install the O-ring on both of the pump tube fittings
and lightly lubricate.
Figure 6-26
11. Place an O-ring on the valve inlet fitting and lightly
lubricate.
Figure 6-27
12. Place the black rubber poppet into the small end of
the tapered spring and assemble the spring onto the
valve inlet fitting.
Figure 6-28
13. Insert the parts assembled in step 12 into the valve
outlet fitting.
Figure 6-29
14. Slide the pressure relief valve onto the main pump
assembly.
Figure 6-30
15175
Apply the appropriate
Taylor approved food safe lubricant.
15176
Apply the appropriate
Taylor approved food safe lubricant.