EasyManua.ls Logo

TDK-Lambda GENESYS 1500W - Page 74

TDK-Lambda GENESYS 1500W
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
83
-
507
-
013 Rev. D
66
3.
Status Enable Register
The Status Enable Register is set by the user to Enable SRQs for changes in power supply status.
Table 7
-
12: Status Enable Register
BIT
Status name
Status sy
m
bol
Bit
Set cond
i
tion
Bit reset condition
0 (LSB)
Constant Voltage
CV
1
Constant Current
CC
2
No Fault
NFLT
3
Fault active
FLT
User command:
“SENA nn” is
r
e
ceived, where
nn is hexadec
i
mal
bits.
User command: “SENA nn”
is received, where nn is
hexadecimal bits.
If “nn”=00, no SRQ is sent
when there is a change in
S
tatus Condition Register.
4
Auto
-
Restart e
n
abled
AST
Always zero
Always zero
5
Fold enabled
FDE
Always zero
Always zero
6
Spare
Spare
Always zero
Always zero
7 (MSB)
Local Mode
LCL
“SENA
nn”
command
“SENA nn”
command
4.
Status Event Register
The Status Event Register will set a bit if a change in the power supply status occurs and it is e
n-
abled. The register is cleared when the “SEVE?” or “CLS” commands are received.
A change in this
register will generate SRQ.
Table 7
-
13: Status Event Register
BIT
Status name
Status sy
m
bol
Bit Set cond
i
tion
Bit reset condition
0 (LSB)
Constant Voltage
CV
1
Constant Current
CC
2
No Fault
NFLT
3
Fault active
FLT
Changes in status
occur and it is
E
n
abled.
The change can
set a bit, but whe
n
the change clears
the bit remains
set.
4
A
uto
-
Restart e
n
abled
0
Always zero
5
Fold enabled
0
Always zero
6
Spare
0
Always zero
7 (MSB)
Local Mode
LCL
Unit is set to L
o
cal
by pressing front
panel REM/LOC
button.
Entire Event Register is
cleared when user sends
“SEVE?” command to read
the register.
“CLS” and power
-
up also
clear the Status Event
Register.