7.8.8 Status Commands
Refer to section 9.3.1, 9.3.2 for Register definitions.
# Command Description
1 STT?
Reads the complete power supply status.
Returns ASCII characters representing the following data, separated by commas:
MV<actual (measured) voltage> PC<programmed (set) current>
PV<programmed (set) voltage> SR<status register, 4-digit hex>
MC<actual (measured) current> FR<fault register, 4-digit hex>
Example response: MV(45.201),PV(45),MC(4.3257),PC(10),SR(0030),FR(0000)
2 FLT? Reads Fault Conditional Register. Return 4-digit hex.
3 FENA Set Fault Enable Register using 4-digit hex.
4 FENA? Reads Fault Enable Register. Returns 4-digit hex.
5 FEVE? Reads Fault Event Register. Returns 4-digit hex. Clears bits of Fault Event Register.
6 STAT? Reads Status Conditional Register. Returns 4-digit hex.
7 SENA Sets Status Enable Register using 4-digit hex.
8 SENA? Reads Status Enable Register. Returns 4-digit hex.
9 SEVE? Reads Status Event register. Returns 4-digit hex. Clears bits of Status Event register.