EasyManuals Logo

Teac C-1 User Manual

Teac C-1
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
10.
11.
$2:
13.
OSCILLOSCOPE
OSCILLATOR
O
@®®
AC
Voltmeter
DECK
under
TEST
oureuT
1%
T~1367
Fig.
6-9
Connection
Set
the
RECORD
controls
to
obtain
a
reading
of
—5
dB
(436
mV)
on
the
AC
voltmeter.
Change
the
AC
voltmeter
connection
to
test
point
|
on
the
DOLBY
ENCODER,
of
both
L-
and
R-channels,
and
set
the
NR
SYSTEM
switch
to
the
DOLBY
position.
Check
that
the
level
at
test
points
is
within
—2.5
dB
+0.5
dB
(548
mV
to
615
mV).
The
determined
physical
position
of
the
RECORD
controls
thus
set
indicates
the
specified
RECORD
control
setting
referred
to
in
subsequent
procedures.
IMPORTANT:
After
this
setting
has
been
made,
do
not
disturb
the
specified
control
setting
of
the
RECORD
control
until
the
remaining
checks
and
adjustments
are
completed.
6-5
PEAK
LEVEL
METER
ADJUSTMENTS
6-5-1
PEAK
LEVEL
METER
CALIBRATION
(INDICATION
AND
LINEARITY)
RECORD
.
With
the
conditions
given
in
paragraph
6-4-2,
adjust
R867/
R868
so
that
the
meters
indicate
O
dB.
.
Change
the
input
level
to
—39
dB
(8.69
mV)
and
adjust
R869/R870
so
that
meters
indicate
—30
dB.
.
Repeat
these
two
adjustments
until
the
following
re-
querements
are
obtained.
.
Set
the
input
levels
and
check
that
the
linearity
at
0,
10,
—20,
—30
and
—40
dB
points
on
the
meter
scale
are
within
the
following
limits
for
each
level
range.
—5
dB
to
+5
dB=+1
dB
—20
dB
to
-6
dB
+
2.5
dB
—21
dB
and
over
=
+3.0
dB
6-5-2
PEAK
LEVEL
METER
CALIBRATION
PLAYBACK
Specification:
0
dB
(
OO
)
5.
6.
7,
Load
and play
a
TEAC
MTT-150
test
tape.
Set
the
MONITOR
switch
to
the
TAPE
OUTPUT
posi-
tion.
Make
sure
that
output
from
the
deck
is
—S dB
(436
mV).
If
not,
correct
this
by
rotating
the
OUTPUT
control.
.
Adjust
R807/R808
so
that
the
meter
indicates
0
dB.
.
Change
the
MONITOR
switch
setting
to
CAL
position
and
confirm
that
the
meter
also
reads
0
dB.
6-6
RECORDING
PERFORMANCE
NOTE:
Before
making
any
adjustments
of
the
recording
circuit,
be
sure
that
all
tests
in
the
above
perform-
ance
sections
have
been
accomplished.
PLAYBACK
and
MONITOR
performance
must
be
properly
adjusted,
otherwise
record
calibration
will
be
in-
accurate.
6-6-1
BIAS
TRAP
ADJUSTMENTS
AC
Voltmeter
TP
2(R-ch)
gre
1
ON
OSC PCB
t
Fig.
6-10
Bias
trap
adjustment
setup
T.P3(L-ch)
ON
OSC PCB
ves
RECORD
7
HEAD
17-1489
NOTE:
The
AC
voltmeter
used
in
this
procedure
must
have
input
impedance
of
1M
ohm
or
more.
1.
Load
a
blank
tape.
2.
Place
the
deck
in
the
RECORD-PAUSE
mode
with
no
signal
applied.
3.
Adjust
L801/L802
for
a
minimum
reading
between
the
T.P.2
(for
R-ch)
or
T.P.3
(for
L-ch)
and
T.P.1
on
the
——
OSC
PCB
ass’y
See
Fig.
6-10.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Teac C-1 and is the answer not in the manual?

Teac C-1 Specifications

General IconGeneral
BrandTeac
ModelC-1
CategoryCassette Player
LanguageEnglish

Related product manuals