EasyManua.ls Logo

Techno CNC Systems 60120 - Page 57

Default Icon
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
57
Call: 1-631-648-7481 or Visit: support.technocnc.com
Titan Series WinCNC Manual
WinCNC
WinCNC Controller
WinCNC Users Guide Page 97
L55 Pump Velocity Mode On
Enables velocity matched pump control.
L56 Pump Purge Mode On
Sets pump to purge mode.
L57 Pump Off
Stops the pump.
L58 Pump Off with Auto Reverse
Stops the pump, using auto reverse.
L59 Set Up Pump Max - L59 M#
Sets the pump max to the specied M parameter.
L60 Turn Virtual Input Off - L60 C#
Turn specied virtual input off, # can be 1-64.
L61 Turn Virtual Input On - L61 C#
Turn specied virtual input on, # can be 1-64.
L70 Re-Enter Last Command
When L70 is used in a le, the last used command will automati-
cally be re-entered on the command line after le completion.
L82 Measures the Surface - L82 Z#
L82 Z# measures the surface with the probe and sets the mea-
sured point to the Z value given.
L82 alone will set the measured point to Z0.
L82.1 Sets the Surface for Probe Digitization
Sets a G92 for vertical axis based on the L82.3 calibration.
L82.2 Moves the Surface for Probe Digitization
Adjusts G92 positions set by the last L82.1 based on a new mea-
surement.
Command Reference